Type N VNA Calbration Kit (DC - 3 GHz) - MTC-20205



Details  
 

Features:

ο Type N50Ω Coaxial Port
ο Broadband: DC-3GHz
ο Fixed Load


General Description:

The MTC-20205 Type N 50Ω coaxial calibration kit is a kind of instrument calibration kit, which can satisfy all demands except measure laboratory. It can be used to calibrate vector network analyser with type N port. The kit contains the following items:

Serial Number

Model

Name

amount

remark

1

MTC-81801A

Type N male open

1

 

2

MTC-81802A

Type N female open

1

 

3

MTC-81803A

Type N male short

1

 

4

MTC-81804A

Type N female short

1

 

5

MTC-70503

Type N female load

1

 

6

MTC-70504

Type N male load

1

 

7

MTC-71101A

N-50KK adapter

1

 

8

MTC-71102A

N-50JJ adapter

1

 

9

MTC-81101A

N-50JK adapter

1

 

10

 

Type N torque wrench

1

 

 

Specifications:

1. Electrical Specifications(Temperature:23±3°C?Frequency Range:DC~3GHz)

Model

Name

Specification

MTC-81801A

Type N male open

Deviation from Nominal Phase
±0.85°

MTC-81802A

Type N female open

MTC-81803A

Type N male short

Deviation from Nominal Phase
±0.65°

MTC-81804A

Type N female short

MTC-70503

Type N female load

VSWR≤1.014

MTC-70504

Type N male load

MTC-71101A

N-50KK adapter

VSWR≤1.029

MTC-71102A

N-50JJ adapter

MTC-81101A

N-50JK adapter

 

Type N torque wrench

Torque Setting 135.6 N.cm±4.1 N.cm

 

2. Environmental Requirements

Operating temperature: 23°C±3°C
Storage temperature: -20°C to +70°C

Ordering Information:

MTC-20205

Type N50Ω Coaxial Calibration Kit

 

Notes:

1. WHEN USING, PLEASE ADOPT ELECTROSTATIC SENSITIVE DEFENSE STEP.

2. BEFORE USING, INSPECT THE CONNECTOR TO MAKE SURE NO PARTICLES OR RESIDUE ARE PRESENT; PLEASE INSURE PIN DEPTH OF DEVICES CONNECTED TO BE UP TO THE STANDARD.

3. WHEN USING, DO NOT TURN THE DEVICE BODY. ONLY TURN THE CONNECTOR NUT. DAMAGE TO THE CENTER CONDUCTOR CAN OCCUR IF THE DEVICE BODY IS TWISTED.

4. USING A TORQUE WRENCH GUARANTEES THAT THE CONNECTION IS NOT TOO TIGHT, PREVENTING POSSIBLE CONNECTOR DAMAGE.

5. WHEN NOT IN USE, PLEASE INSTALL THE PROTECTIVE END CAPS AND STORE THE CALIBRATION DEVICES IN THE FOAM-LINED STORAGE CASE.

6. PLEASE VERIFY THE PERFORMANCE OF YOUR CALIBRATION KIT IN A PERIOD OF TIME BY THE QUALIFIED.

7. PRODUCT SPECIFICATIONS AND DESCRIPTIONS IN THIS DOCUMENT ARE SUBJECT TO CHANGE WITHOUT NOTICE.




  • Share with Us:




  • Company

    Microwave Town LLC is a leader in the microwave component industry. We offer a wide range of high quality, precision RF products such as coaxial and waveguide components, broadband power amplifiers, and antennas for DC to 330 GHz. Our millimeter wave products are carefully designed and widely used in military and commercial applications. It is our focus to meet your stringent specifications and requirements. We are committed to providing our customers with the highest quality products, competitive pricing, fast delivery, and excellent customer service.